Close

VESDA-E VEA

Nitrogen Dioxide 5 to 50 ppm - 4-20mA Analogue, Relay

P-XCL-LB-NO2-RA

VESDA Sensepoint XCL – Large Bore is a gas detection solution that utilizes the ASD pipe network to deliver superior gas detection via multiple hole (multi-point) sampling. The combined solution provides reliable detection of gases for occupant protection and process monitoring whilst simultaneously ensuring protection against fire threats. The VESDA Sensepoint XCL – Large Bore portfolio has a range of gas sensors that addresses a wide range of applications and through its Bluetooth interface can be paired with a smart device for commissioning and maintenance. The smart device application (Sensepoint App) provides quick access to detector diagnostic information and simplifies detector configuration, calibration and bump testing.

VESDA Sensepoint XCL – Large Bore is a gas detection solution that utilizes the ASD pipe network to deliver superior gas detection via multiple hole (multi-point) sampling. The combined solution provides reliable detection of gases for occupant protection and process monitoring whilst simultaneously ensuring protection against fire threats. The VESDA Sensepoint XCL – Large Bore portfolio has a range of gas sensors that addresses a wide range of applications and through its Bluetooth interface can be paired with a smart device for commissioning and maintenance. The smart device application (Sensepoint App) provides quick access to detector diagnostic information and simplifies detector configuration, calibration and bump testing.

Downloads

OTHER

Technical Details

  • Dimensions : 113 x 113 x 59 mm (4.4 x 4.4 x 2.3 in)
  • Humidity Range : 0 to 99% (non-condensing) CAT versions: 10 to 90% RH. Operating the detector outside this range may result in increased drift and a reduction in detector accuracy.
  • IP Rating : IP65, Type 4 (NEMA 250)
  • Material : Casing: Polycarbonate
  • Operating Temperature : −20 to +50 °C (−4 to +122 °F)
  • Outputs : Analog: 0 to 22 mA Digital: Modbus RTU 2 Relays (24V DC / 240V AC, 5A)
  • Pipe Size : Connects to ASD pipe networks 25mm (0.98”), 27mm (1.06”) OD

Product Information

How it works

VESDA Sensepoint XCL – Large Bore is designed to be easily incorporated to existing or new ASD pipe networks without major construction or electrical cabling / conduit and utilizes the flow in the pipe for the continuous delivery of air samples to the gas sensor for analysis. It is capable of remote sampling which means the detector can be placed outside the detection zone at a convenient location for maintenance and service where free business operation, restricted access and safety of personnel is important. Air drawn to the detector can be conditioned to remove contaminates which ensures the detector maintains reliable long-term performance in a wide range of environments. A single VESDA Sensepoint XCL – Large Bore detector delivers multi-point gas sampling capability giving it the advantage of providing larger coverage, increased design flexibility and reliable detection in high airflow areas compared to fixed point gas detectors.

Flexible Output Options

VESDA Sensepoint XCL – Large Bore is available with either 4-20 mA analog or Modbus RTU output, both versions being equipped with relays. The result is a flexible solution that can be integrated to BMS, fire alarm panels, PLCs, HVAC, etc.

Applications

  • Energy storage systems (batteries)
  • Fuel storage and distribution lines
  • Service tunnels
  • Confined / Underground areas
  • Heating plant rooms
  • Manufacturing / Petroleum / Chemical industries
  • Parking garages / Loading bays
  • Power generation
  • Refrigerated storage
  • Waste handling facilities / Landfill sites
  • Agriculture
  • Water treatment / Sewerage plants
  • Health care / Hospitals / Laboratories
  • Food / Beverage industry
  • Vehicle test facilities

Features

  • Wide range of gases to support most application needs:
      • Carbon Monoxide (CO, ppm)
      • Flammable gases (% LEL)
      • Oxygen (O2, % v/v)
      • Carbon Dioxide (CO2, % v/v, ppm)
      • Hydrogen (H2, ppm)
      • Hydrogen Sulphide (H2S, ppm)
      • Nitrogen Dioxide (NO2, ppm)
      • Ammonia (NH3, ppm)*
    • Aspirated gas sampling technology:
      • Multi-point sampling provides greater coverage and increased design flexibility
      • Remote sampling eliminates the need to enter the protected zone
      • Centralized location saves time & money for service and maintenance
      • Detector protection against environmental conditions ensures reliable long term operation
    • Integral alarm status LEDs
    • Integral gas port for bump test and calibration
    • Field replaceable gas sensor cartridges
    • Smart device application (Sensepoint App) enables faster detector commissioning, maintenance and service
    • Multiple output options (2 x configurable relays, 4-20 mA or Modbus RTU) for Alarm and Fault reporting

    Approvals

    • Electrical safety
      • Conforms to EN/UL/IEC 61010-1
      • Certified to CSA-C22.2 No. 61010- 1-12
    • CE - EMC
      • EN 50270
    • RADIO
      • RED, FCC, BT SIG
    • OTHERS
      • UL2075 (CO and CH4 ), AS 1668.2

    30 other products in the same category

    Close